Before/after on a 200A panel replacement — Square D QO200

Customer called with a Federal Pacific Stab-Lok that had been on a home inspector's report for 3 years. Owner finally pulled the trigger after selling the house fell through over it.

Pulled the old FPE, installed a Square D QO200L200PG with a 30-space box. Took the opportunity to separate the neutrals and grounds throughout, add AFCI on the bedroom circuits, and label everything properly.

Previous electrician had used push-in connectors on 10AWG — on a dryer circuit. Those came out immediately.

Threw in a couple pics of the before and after. The before is genuinely terrifying.

💬 4 replies

Log in or sign up to leave a reply.

u/breaker_bob

Push-ins on 10AWG dryer circuits are how houses burn down. Good catch. I've seen 6AWG on push-ins too — some contractors clearly never read the device ratings.

114
u/conduit_king

That before picture is nightmare fuel. Good work getting that out.

104
u/sparky420

FPE Stab-Loks keep me employed. Nice clean install — I like seeing the neutrals and grounds separated properly. Too many guys skip that on replacements.

101
u/nec_nerd

200-amp service, 30 space, QO — solid choice. Did you run the new meter base or was that already 200A? Some of these older FPE installs were undersized at the meter too.

9