Intermittent no-start on a 2019 Ram 2500 6.7 — 14 days of nothing, then it did it in the bay Diagnostics
Fleet truck, intermittent crank-no-start. Maybe once every ten days. Driver says it cranks normally and just does not catch, then twenty minutes later it starts fine.
Two weeks of it sitting in my bay behaving perfectly. Datalogger on it the whole time.
Today it finally did it with me standing there. Captured:
- Crank RPM normal, 210 RPM
- Cam and crank signals both present and correlated
- Rail pressure during crank: 4,100 PSI (needs about 5,000 to fire)
- Fuel temp 34°F, ambient 39°F
- After 20 min in the warm bay: rail pressure 6,200 PSI on crank, fires immediately
So it is a rail pressure problem that is temperature dependent. The obvious answer is the CP4 giving up, but the truck runs perfectly once started and has no other symptoms, no metal in the filter, and the fuel is clean.
Before I sell this fleet a pump, what else produces low crank rail pressure only when cold?